Instruction
Sheet
Part No...........................................
With representatives offices in principal cities throughout North America.
Copyright , revision, All Rights Reserved - Printed in U.S.A.
701 Millennium Blvd., Greenville, SC 29607
www.prescolite.com y Prescolite Toll Free Technical Support 1.888.PRS.4TEC y Hours: 8am - 5pm ET
IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information
and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,
and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and
during servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by
qualified service personnel. Product must be grounded to avoid potential electric shock or other potential hazard.
Product must be mounted in locations and at heights and in a manner consistent with its intended use, and in
compliance with the National Electrical Code and local codes. The use of accessory equipment not recommended b
y
the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from
product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens o
r
the like to come into contact with the product or to block li
g
ht from the product, as this ma
y
cause an unsafe condition.
93040526
2012
01/25/12
WARNING
This product contains chemicals known to the State of California to cause cancer, birth defects and/or othe
r
reproductive harm. Thorou
g
hl
y
wash
y
our hands after installin
g
, handlin
g
, cleanin
g
, or otherwise touchin
g
this product.
CAUTION: DO NOT ATTEMPT TO MODIFY OR REWIRE FACTORY-INSTALLED WIRING ON THE FIXTURE. SAFETY AND
PROPER OPERATION OF THE FIXTURE DEPEND ON THE INTEGRITY OF THE WIRING.
KEEP THESE INSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS
MODEL D2ICAT
C
E
N
T
E
R
L
I
N
E
C
E
N
T
E
R
L
I
N
E
1. The bar hanger brackets are sh ipped flat. Bend the ta b s on
the brackets a s show n to allow the use of a cce sso ry m ounting
channels or bar hangers (Presco lite B6, B24, or by others).
M ount the fram e in the ceiling so that the w eight of the
a sse m b ly is sa fely supported by the m ounting channel or bar
and/or hanger wire s secured to the building structure.
2. Rem ove the top of the h o u sing and adju st the fram e so the
bottom su rface is flu sh with the ceiling m aterial m ounting
su rfa ce (backside of the ceiling m aterial) and in alignm ent
with adja cent fixture s. The rivets for the 8 x 8
polyca rbonate cut-through panel m ay be used a s centerlines
(a s show n) for aligning the fram e. Secure the m ounting
bra ckets by tightening wing nuts on either side of the fram e
in side the D2IC A T h o using.
3. Important! When the ceiling material is added
(covering the D2ICAT) make sure the D2ICAT is
flush with the back side of the ceiling material and
solidly mounted. Mark the fixture installation
location accurately so the hole cut-through location
will be accurate!
4. There are four 3/8” M C flexible conduit entry points located
on the rear cover plate of the D2IC A T to allow the
UNENERGIZED line voltag e and
control (0-10V dimming)
flexible conduit to be inserted into the h o u sing until they are
used w hen the D2LED fixture is wired and in stalled. There are
four conduit g a sk ets included with the D2IC A T h o u sing to be
used if needed to se a l the conduit opening further after the
flexible conduit is in stalled. Th ere is also a tether cable
m ounted in side the h o u sing to be attached to the D2LED
fixture in the ca se of se ism ic conditio n s at the in stall location.
This tether, if needed, sh o uld be attached to the screw on the
light engine (see Figure A) after the wiring is com plete and
the J-tube is inserted in the ceiling, but before fixture is
in stalled.
5. In stall the D2LED fixture per the in struction sheet pro vided with
the fixture. W hen the hole is cut in the ceiling with the 2-7/8”
hole sa w (by others), it will cut through the ceiling m aterial
and the D2IC A T polycarbonat
e cut-through panel at the sa m e
tim e pro viding accurate alignm ent in both the ceiling m aterial
and the D2IC A T.
6. WARNING: DO NOT pinch wires between J-tube
cover and J-tube endplates. Consult a Qualified
Electrician for all other options that require other
wiring configurations.
DETAIL A
D2ICAT WITH D2LED INSTALLED
8" x 8"
Polycarbonate
Panel
Cut-Through
Area
Siesmic
Tether
D2LED
Fixture Screw
3/8" Flexible
Conduit
Entry Points
Extra
Conduit
Gaskets
A
InstructionSheet
www.prescolite.com Prescolite TollFree Technical Support 1.888.PRS.4TEC Hours: 8am - 5pm ET
701 Millennium Boulevard Greenville, SC 29607
With representatives offices in principal cities throughout North America.
Copyright 2012, 2/16/12 revision, All Rights Reserved - Printed in U.S.A.
Part No. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 93040526
InstructionSheet
INSTALLATION INSTRUCTIONS
MODEL D2ICAT
IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and
instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and
proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and during
servicing or relamping, turn off power at fuse or circuit breaker. All servicing or relamping must be performed by
qualified service personnel. Product must be grounded to avoid potential electric shock or other poten-
tial hazard. Product must be mounted in locations and at heights and in a manner consistent with its
intended use, and in compliance with the National Electrical Code and local codes. The use of accessory
equipment not recommended by the manufacturer or installed contrary to instructions may cause an unsafe condition. Do
not block light emanating from product in whole or part, as this may cause an unsafe condition. Do not allow items such
as drapes, curtains, screens or the like to come into contact with the product or to block light from the product, as this may
cause an unsafe condition.
WARNING - This product contains chemicals known to the State of California to cause cancer, birth defects and/or other
reproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this product.
CAUTION: DO NOT ATTEMPT TO MODIFY OR REWIRE FACTORY-INSTALLED WIRING ON THE FIXTURE. SAFETY AND
PROPER OPERATION OF THE FIXTURE DEPEND ON THE INTEGRITY OF THE WIRING.
KEEP THESE INSTALLATION INSTRUCTIONS
1. The bar hanger brackets are shipped flat. Bend the tabs on the
brackets as shown to allow the use of accessory mounting channels
or bar hangers (Prescolite B6, B24, or by others). Mount the frame
in the ceiling so that the weight of the assembly is safely supported
by the mounting channel or bar and/or hanger wires secured to
the building structure.
2. Remove the top of the housing and adjust the frame so the bottom
surface is flush with the ceiling material mounting surface (backside
of the ceiling material) and in alignment with adjacent fixtures.
The rivets for the 8” x 8” polycarbonate cut-through panel may be
used as centerlines (as shown) for aligning the frame. Secure the
mounting brackets by tightening wing nuts on either side of the
frame inside the D2ICAT housing.
3. Important! When the ceiling material is added (covering
the D2ICAT) make sure the D2ICAT is flush with the
back side of the ceiling material and solidly mounted.
Mark the fixture installation location accurately so the
hole cut-through location will be accurate!
4. There are four 3/8” MC flexible conduit entry points located on the
rear cover plate of the D2ICAT to allow the UNENERGIZED line
voltage and control (0-10V dimming) flexible conduit to be inserted
into the housing until they are used when the D2LED fixture is wired
and installed. There are four conduit gaskets included with the
D2ICAT housing to be used if needed to seal the conduit opening
further after the flexible conduit is installed. There is also a tether
cable mounted inside the housing to be attached to the D2LED
fixture in the case of seismic conditions at the install location. This
tether, if needed, should be attached to the screw on the light
engine (see Detail A) after the wiring is complete and the J-tube is
inserted in the ceiling, but before fixture is installed.
5. Install the D2LED fixture per the instruction sheet provided with
the fixture. When the hole is cut in the ceiling with the 2-7/8”
hole saw (by others), it will cut through the ceiling material and
the D2ICAT polycarbonate cut-through panel at the same time
providing accurate alignment in both the ceiling material and the
D2ICAT.
6. WARNING: DO NOT pinch wires between J-tube cover
and J-tube endplates. Consult a Qualified Electrician
for all other options that require other wiring
configurations.
Seismic
Vue de la page 0
1

Résumé du contenu

Page 1 - InstructionSheet

InstructionSheetPart No............With representatives offices in principal cities throughout North America.Copyright

Commentaires sur ces manuels

Pas de commentaire