InstructionSheet
www.prescolite.com Prescolite TollFree Technical Support 1.888.PRS.4TEC Hours: 8am - 5pm ET
701 Millennium Blvd, Greenville, SC 29607
With representatives offices in principal cities throughout North America.
Copyright 2010,
1/6/10
, All Rights Reserved - Printed in U.S.A.
Part No ....................................................... 93026630
Sheet 1 of 2
IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information and instructions
concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials, and proper lamping. Do
not install in areas subject to combustible vapors or gases. Before wiring to power supply and during servicing or relamping, turn
off power at fuse or circuit breaker. All servicing or relamping must be performed by qualified service personnel.
Product must be grounded to avoid potential electric shock or other potential hazard. Product must be
mounted in locations and at heights and in a manner consistent with its intended use, and in compliance
with the National Electrical Code and local building codes. The use of accessory equipment not recommended by the
manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from product in
whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or the like to come into
contact with the product or to block light from the product, as this may cause an unsafe condition.
WARNING - This product contains chemicals known to the State of California to cause cancer, birth defects and/or other
reproductive harm. Thoroughly wash hands after installing, handling, cleaning, or otherwise touching this product.
NOTE: Complete installation video can be seen at: www.prescolite.com. On homepage select: Media > Videos > Retroficient.
PREPARATION: Current reflector and lamp must be removed. Supply line must be disconnected to current socket. The current
socket can be set aside above the ceiling or removed completely. Power must be turned off and the supply line must be
brought to the opening in ceiling as shown on page 2.
A. Connect quick connect (1) to the supply line. Remove junction box cover (3) attach supply line to junction box (4) through
one of the knock-outs provided in junction box (4). Attach connector (1) to connector (2). Put all wires inside of junction box
(4) and install junction box cover (3). (SEE FIG. 1)
WARNING: DO NOT pinch wires between J-Box/ballast cover and J-Box. Consult a qualified electrician for all other options
that require other wiring configurations. Make sure all connections are tight and secure.
B. Slip junction box Assembly and Ring “A” through hole in ceiling. (SEE FIG. 1)
C. Position RING “A” by centering it on ceiling opening. Hold RING “A” down against the top of ceiling and install two clips
(6) by pushing lower portion of clip (6) onto lip of metal flange in ceiling cut out while aligning the slot in clip (6) with the
screws (7) in Ring “A”. With Ring ‘A” centered and pressed down firmly, tighten two screws (7) to secure. (SEE FIG 2 and 3)
RING ‘A” can be rotated as needed to clear existing fixture obstacles and/or to be positioned best for the flexible conduit,
etc. Prior to tightening two screws (7) in clips (6). If additional adjustment is needed, screw (8) and/or screw (9) can be
loosened and junction box (4) can be further moved. Ensure that screw (8) and (9) are retightened after this step. (SEE FIG. 5)
D. Repeat step C for RING “B”. Ensure that RING “A” and RING “B” are mated and interlocked when securing RING ‘B”.
(SEE FIG 3 and 4)
E. Make sure that housing unit (5) is through ceiling opening. Remove wing nut from socket housing unit. Place three small
reflector holes around post and two extrusions of the socket housing unit. If the reflector (10) has dissimilar lamp windows,
the largest lamp window needs to face the lampholders Place wing nut back onto post over the reflector; then tighten.
Lampholder(s) will be aligned with lamp windows in reflector.
F. Install socket housing unit (5) through ceiling opening facing away from the J-Box (4). Push reflector (10) towards ceiling
until reflector flange is flush against the ceiling. (SEE FIG. 7)
G. Install proper lamp/s.
SEE PAGE 2 FOR ILLUSTRATIONS
INSTALLATION INSTRUCTIONS
RLF6CFHSD AND RLF8CFHSD
Vue de la page 0
1 2

Résumé du contenu

Page 1 - InstructionSheet

InstructionSheetwww.prescolite.com Prescolite TollFree Technical Support 1.888.PRS.4TEC Hours: 8am - 5pm ET 701 Millennium Blvd, Gree

Page 2

InstructionSheetwww.prescolite.com Prescolite TollFree Technical Support 1.888.PRS.4TEC Hours: 8am - 5pm ET 701 Millennium Blvd, Gree

Modèles reliés RLF6CFHSD

Commentaires sur ces manuels

Pas de commentaire