www.prescolite.com Prescolite TollFree Technical Support 1.888.PRS.4TEC Hours: 8am - 5pm ET

With representatives offices in principal cities throughout North America.
Copyright 2011, 8/2/11 revision, All Rights Reserved - Printed in U.S.A.
Instruction Sht. No.........................93037150
When installed according to the instructions provided and as specified in volume 1 of the UL Fire Resistance Directory,
Prescolite FT6QLIC
luminaire may be used in fire resistance Floor-Ceiling and Roof-Ceiling designs. See File
under Fire Classified Directory CDHW.

Instruction
 - If any special control devices are used with this fixture, follow the instructions carefully to assure full compliance with N.E.C. requirements.
If there are any questions, contact a qualified electrical contractor.
 Use only those trims, lamps and maximum wattages proper for this fixture, as indicated on the label within the fixture housing.
 The National Electrical Code, Article 110-3 (b), states that “Listed or Labeled equipment shall be used or installed in accordance with any
instructions included in the listing or labeling”. Use only with Prescolite UL listed trims. Use of other trims not listed in this fixture, including those that are
UL classified, is a violation of N.E.C. 110-3 (b) and voids all warranties.
 FT6 and FT6CF2H are type non-ic fixtures. Insulation must be kept at least 3” from fixture sides to prevent lamp cycling.



1. Slip Bar Hangers (1) into channels in Plaster Frame (2). Hold Frame in desired position between Joists (3) and drive
Bar Hanger Tabs (4) into Joists. Use a minimum 1” lg. steel Nail or Screw (26) through holes in Bar Hanger ends for
additional support. Tighten bar hanger Locking Screws (5) in ends of Plaster Frame to prevent lateral movement of Plaster
Frame. (See Fig. 1 and 2)
2. Remove Cover Plate (9) from Junction Box (10). Slip Type NM Cable (Romex) (11) through desired hole in Junction
Box (10) above Retaining Plate (13). Cable (11) is secured by Retaining Plate (13). (See Fig. 3)
3. If other than Type NM Cable (Romex) is to be used, remove one Large Knockout (15) at desired location on top or
sides of Junction Box (10). Bring appropriate Electrical Supply Cable into Junction Box and secure in place with proper
UL listed Connector (NOT FURNISHED).
4. Connect Fixture Wires (27) to Supply Wires (16) as shown in Wiring Diagram. Use UL listed Wirenuts (NOT
FURNISHED).
5. After ceiling is finished lower Housing (6) until flush with Ceiling.
6. To gain access to Junction Box (10), after ceiling is finished, remove three Screws (24) that hold Housing (6) in place.
Lower the Housing. Remove Screw (21) and Access Door (22) located inside Fixture. Junction Box Cover Plate (9) can
now be removed for service.
7. Plaster Frame (2) and Gasket (25) must be in contact with Ceiling (23).
8. If joists are spaced greater than 16 inches on center, 2x4 (4 inch dimension vertical) or greater lumber shall be used
to span between joists at the plane of the ceiling to create a 16 inch on center space to mount the fixture as shown
in Fig. 4.

 Upon completion of installation, crumple this
sheet up and insert it up into the housing to protect the socket and labels from being spray painted.
IMPORTANT SAFETY INFORMATION. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. Follow label information
and instructions concerning Wet or Damp Locations, installation near combustible materials, insulation, building materials,
and proper lamping. Do not install in areas subject to combustible vapors or gases. Before wiring to power supply and
during servicing or relamping, turn off power at fuse or circuit breaker. 


 The use of accessory equipment not recommended by
the manufacturer or installed contrary to instructions may cause an unsafe condition. Do not block light emanating from
product in whole or part, as this may cause an unsafe condition. Do not allow items such as drapes, curtains, screens or
the like to come into contact with the product or to block light from the product, as this may cause an unsafe condition.


Vue de la page 0
1 2 3

Résumé du contenu

Page 1 - Instruction

www.prescolite.com • Prescolite TollFree Technical Support 1.888.PRS.4TEC • Hours: 8am - 5pm ET

Page 2

www.prescolite.com • Prescolite TollFree Technical Support 1.888.PRS.4TEC • Hours: 8am - 5pm ET

Page 3

 1. Att

Commentaires sur ces manuels

Pas de commentaire